YELLOW JACKET 93600 Evacuation Pump, 7 CFM, 1/2 HP, 1725RPM | AA2JTG 10M826

YELLOW JACKET 93600 Evacuation Pump, 7 CFM, 1/2 HP, 1725RPM

Item: AA2JTGModel: 93600Cross Ref: 10M826
In Stock

Get it by Monday, Jun 16

€904.85 /unit
Add To Cart
Request a Quote

Payment

Product Specifications:

ItemEvacuation Pump
Body MaterialAluminum
Cord6 ft.
Displacement7 CFM
Housing MaterialAluminum
Hp1/2 hp
Number Of Stages2
Oil Capacity28 oz.
Overall Height11 1/2"
Overall Length16 1/4"
Overall Width6"
Promotion RestrictionNot Eligible For Promotion
Thermal Overload ProtectionYes
Voltage115V AC
A2l CompatibilityA2L Compatible
Calibration Certificate TypeNot Certified
Cord Length6 ft.
Drain Port Connection Thread DirectionRight-Hand
Drive TypeDirect Drive
For Refrigerant TypeR-11, R-113, R-1130, R-1132, R-1132A, R-114, R-115, R-1150, R-116, R-12, R-1224YD, R-123, R-1233ZD, R-1234YF, R-1234ZE, R-124, R-125, R-1270, R-12B1, R-13, R-1336MZZ, R-134A, R-13B1, R-13I1, R-14, R-141B, R-142B, R-143A, R-14E, R-152A, R-161, R-170, R-21, R-218, R-22, R-227, R-227EA, R-23, R-236FA, R-245FA, R-25, R-290, R-30, R-31, R-32, R-40, R-400, R-400A, R-401A, R-401B, R-401C, R-402A, R-402B, R-403A, R-403B, R-404A, R-405A, R-406A, R-407A, R-407B, R-407C, R-407D, R-407E, R-407F, R-407G, R-407H, R-407I, R-408A, R-409A, R-409B, R-41, R-410A, R-410B, R-411A, R-411B, R-412A, R-413A, R-414A, R-414B, R-415A, R-415B, R-416A, R-417A, R-417B, R-417C, R-418A, R-419A, R-419B, R-420A, R-421A, R-421B, R-422A, R-422B, R-422C, R-422D, R-422E, R-423A, R-424A, R-425A, R-426A, R-427A, R-427C, R-428A, R-429A, R-430A, R-431A, R-432A, R-433A, R-433B, R-433C, R-434A, R-435A, R-436A, R-436B, R-436C, R-437A, R-438A, R-439A, R-440A, R-441A, R-442A, R-443A, R-444A, R-444B, R-445A, R-446A, R-447A, R-447B, R-448A, R-448B, R-449A, R-449B, R-449C, R-450A, R-451A, R-451B, R-452A, R-452B, R-452C, R-453A, R-454A, R-454B, R-454C, R-455A, R-456A, R-457A, R-457B, R-457C, R-458A, R-459A, R-459B, R-460A, R-460B, R-460C, R-461A, R-462A, R-463A, R-464A, R-465A, R-466A, R-467A, R-468A, R-468B, R-468C, R-469A, R-470A, R-470B, R-471A, R-472A, R-472B, R-473A, R-474A, R-475A, R-476A, R-50, R-500, R-501, R-502, R-503, R-504, R-505, R-506, R-507, R-507A, R-508A, R-508B, R-509A, R-510A, R-511A, R-512A, R-513A, R-513B, R-514A, R-515A, R-515B, R-516A, R-600, R-600A, R-601, R-601A, R-610, R-611, R-620, R-630, R-631, R-702, R-704, R-717, R-718, R-720, R-728, R-732, R-740, R-744, R-744A, R-764, R-A11A, R-C318, R-E170, R-IS89, SP22
Frequency60 Hz
Horsepower1/2 hp
Includes Gas BallastGas Ballast Not Included
Includes Hoist ClipHoist Clip Not Included
Includes Isolation ValveIsolation Valve Not Included
Includes Oil Mist FilterOil Mist Filter Not Included
Includes SightglassSightglass Included
Includes Vacuum GaugeGauge Not Included
Inlet 1 Port Connection GenderMale
Inlet 1 Port Connection Size1/4"
Inlet 1 Port Connection Thread DirectionRight-Hand
Inlet 1 Port Connection TypeFlare
Inlet 2 Port Connection GenderMale
Inlet 2 Port Connection Size3/8"
Inlet 2 Port Connection Thread DirectionRight Hand
Inlet 2 Port Connection TypeFlare
Inlet 3 Port Connection GenderMale
Inlet 3 Port Connection Size3/8"
Inlet 3 Port Connection Thread DirectionRight-Hand
Inlet 3 Port Connection TypeFlare
Motor Speed1725 RPM
Motor TypeAC
Number Of Inlet Ports3
Operating Temperature - Maximum180°F
Operating Temperature - Minimum-32°F
PhaseSingle
Plug Configuration5-15P
Power SourcePlug In
Product TypeVacuum Pump
Reservoir Port Connection Thread DirectionRight-Hand
SeriesBULLET Series
StandardsEAR99
Ultimate Vacuum25 µm
Warranty2 yr.
Weight36.6 lbs.

Shipping Info:

Ship weight (kg) 16.79
Ship height (cm)35.31
Ship length (cm)49.53
Ship width (cm)23.88
HS code8414100000
Country of OriginUS

Product Details:

YELLOW JACKET 93600 evacuation pump is used to evacuate or remove air and moisture from refrigeration systems, ensuring optimal performance and efficiency. This pump is suitable in the installation, maintenance & repair of air conditioning & refrigeration units. Its ability to create a vacuum in these systems facilitates proper refrigerant charging & helps prevent issues such as frost formation & reduced system efficiency.

Features:

  • This Bullet X vacuum pump features an internal intake check valve to prevent oil backup into the system during a power failure.
  • It incorporates an intake filter screen to prevent damaging particles from entering the pump.
  • This equipment is equipped with heavy-duty rotors and bearings, ensuring long-lasting and reliable performance.
  • It features a downward-angled oil sump for effectively removing contaminants.
  • This Bullet X vacuum pump includes a wide-mouth oil reservoir port for easier & cleaner filling.
  • It further features a steel handle, providing durability and ease of portability.
  • This pump is designed with a large brass oil drain for easy access, facilitating quick & efficient oil changes.

Frequently Asked Questions:

Q. What is the significance of Bullet X in YELLOW JACKET 93600 evacuation pump?

A. The significance of the Bullet X in this YELLOW JACKET vacuum pump line lies in its highly efficient two-stage rotary vane design, pulling down to less than 25 microns to protect HVAC systems, coupled with user-friendly features, durability and international adaptability.

Q. What are the factors to consider while choosing an evacuation pump?

A. Major factors include evacuation capacity, micron-pulling capability, durability features, user-friendly design, safety features and applicability to different settings.

Q. What is the purpose of the integrated cooling fins in this Bullet X vacuum pump?

A. The integrated cooling fins play a role in dissipating heat, ensuring the pump operates at an optimal temperature and contributing to overall performance and longevity.

Q. How do I clean and maintain this YELLOW JACKET evacuation pump?

A.

  • Regularly inspect and clean the intake filter screen to prevent damaging particles from entering the pump.
  • Monitor the oil level through the elongated oil sight glass and perform oil changes as recommended using a high-quality vacuum pump oil.
  • Utilise the large brass oil drain for easy access during oil changes.
  • Check the downward-angled oil sump for contaminants and clean it to maintain optimal performance.
  • Inspect the internal intake check valve for proper functioning, particularly during power failures.
  • Keep the wide-mouth oil reservoir port clean for easier and cleaner filling.
  • Examine the heavy-duty rotors and bearings for wear and tear.

Explore Products

Contact us

Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 07:30 until 17:00.

YELLOW JACKET 93600 Evacuation Pump, 7 CFM, 1/2 HP, 1725RPM
€904.85 /unit