Compatible Accessories:
- Trico Oiler Wire Guards: These wire guards protect the reservoir of this oiler from potential accidents.
- Trico 36470 Opto Laser Level: These levelling tools are used to accurately set / level this constant level oiler on the system.
Standards and Approvals:
- ISO 9001:2015
- ISO / IEC 17025:2017
- ASTM
Frequently Asked Questions:
Q. What is the construction material of this Trico 30084 Opto-Matic constant level oiler?
A. This constant level oiler has a transparent butyrate plastic reservoir having a 4-ounce capacity. It further has a lower casting having die-cast zinc construction with bright zinc plating. The unit's internal parts are made of zinc-plated steel.
Q. How is this Trico 30084 Opto-Matic oiler installed on equipment?
A. Trico 30084 Opto-Matic oiler has 1/4 inch NPT connections for easy installation on the equipment.
Q. How to install this Trico 30084 Opto-Matic oiler?
A.
- Before installing, determine the shaft rotation direction.
- Install the oiler on the side of the equipment facing the direction of shaft rotation to prevent misfeeding of the oiler.
- Determine the equipment's proper oil level. Loosen the set screw and remove the reservoir.
- Connect the lower casting of this unit to the bearing chamber using side or bottom connections. Level it properly & mark the desired oil level.
- Measure the distance between the unit and the top edge of the spout angle. Mark this distance above the line made in the above step as X.
- Fill the equipment bearing chamber through the unit's lower casting until the oil level reaches the desired level mark.
- Fill 2/3 of the reservoir with the recommended oil using a funnel. Invert it over the lower casting. Insert the reservoir assembly till its bottom edge reaches the X mark.
- Tighten the set screws on the reservoir assembly and start the process to check for the proper functioning of the oiler.