Item | Controller |
Amps | 1A |
Backlit Screen | Yes |
Backlit Type | Motion Activated |
Connection | Screw Terminals |
Connection Type | Screw Terminals |
Dehumidification Control | No |
Dimensions | 1" x 1.047" |
Display Type | Digital |
Dual Transformer Compatible | Yes |
Electrical Connection Type | Hardwired |
Enclosure Color | White |
For Use With | Rooftop Units, Split Systems |
Housing Color | White |
Housing Material | Plastic |
Housing Type | Flame Retardent Housing |
Humidification Control | No |
Includes | Backplate |
Inputs | Thermistors Type II Or III |
Mounting Direction | Horizontal |
Number Of Cooling Stages (conventional System) | 1 |
Number Of Cooling Stages (heat Pump System) | 1 |
Number Of Heating Stages (conventional System) | 2 |
Number Of Heating Stages (heat Pump System) | 2 |
Number Of Poles | 1 |
Number Of Relay Control Output | 6 |
Number Of Relay Inputs | 0 |
Number Of Relay Inputs/outputs | 0 |
Occupancy Sensor | Includes Onboard Occupancy Sensor |
Overall Depth | 1 1/8" |
Overall Height | 5 1/8" |
Overall Width | 3 1/2" |
Remote Control Functions | Temperature Control |
Screen Height | 1 1/16" |
Screen Width | 1" |
Sensor Length | 33 ft. |
Sensor Location | Remote |
Sensor Type | Thermistor |
Temp. Sensitivity | -0.36°F to +0.36°F |
Thermostat Type | Low Voltage |
Type | Bacnet |
Voltage | 24V AC |
Wireless | Hardwired |
Amperage | 1A |
Application | Heat Or Cool |
Compatible System Type | RTU |
Contact Rating | 24V AC |
Control Output | Single Stage RTU/Heat Pump with Economizer, Two Stage RTU/Heat Pump with Economizer |
Control Type | Push Button |
Frequency | 50/60 Hz |
Humidification/dehumidification Control | No |
Key Features | Economizer, Fan Control, Modulating or On/Off Valves |
Lead Wire Gauge | 14 ga., 22 ga. |
Maximum Operating Temperature | 140°F |
Minimum Operating Temperature | 32°F |
Mounting Location | Wall |
Network Protocol Compatibility | BACnet MS/TP |
Number Of Cooling Stages - Conventional System | 1 |
Number Of Cooling Stages - Heat Pump System | 1 |
Number Of Heating Stages - Conventional System | 2 |
Number Of Heating Stages - Heat Pump System | 2 |
Number Of Pipes | 2, 4 |
Number Of Relay Outputs | 6 |
Standards | ANSI/ASHRAE BACNET STANDARD 135-2008, BACNET TESTING LABORATORY LISTED, FCC CLASS A, PART 15, SUBPART B AND COMPLIES WITH CANADIAN ICES-003 CLASS B, SASO PCP REGISTRATION KSA R-103260, UL 916 ENERGY MANAGEMENT EQUIPMENT |
Switch Type | SPST |
Temperature Adjustment | Floating, On/Off |
Temperature Scale | Fahrenheit/Celsius |
Temperature Sensitivity | +/-0.36°F |
Terminal Designations | -A, +B, AO6, AO7, AO8, BO5, COM, DAT, FAN-H, FAN-L, FAN-M, GND, RBO4, RS, WST |