Flat Shipping

Flat Shipping at €9,00 + VAT

On orders above €99,00

DAYTON 2TGA5 Fire Damper, Static, 5-3/4 x 11-3/4 x 3-3/4 Inch Size, Vertical | AC3GWX

DAYTON 2TGA5 Fire Damper, Static, 5-3/4 x 11-3/4 x 3-3/4 Inch Size, Vertical

In Stock
Item: AC3GWX Model: 2TGA5

Get it by May 24, Friday

Product available for flat shipping. Flat shipping price of €9,00 on transactions of value €99,00 or more and aggregate weight below 10 pounds.

Delivery Options:

Int. Economy (6-10 days)
  • Int. Express (5-7 days) ¥3,750
  • Ex-Works Pickup Free
  • Ex-works Pickup
€80.35 /unit
Add To Cart
Request a Quote

Payment Methods

Delivery Partners

Product Specifications:

ItemFire Damper
Air Flow DirectionVertical
ApplicationFire
Blade FinishGalvanized
Blade MaterialSteel
Blade TypeCurtain
Closure TypeGravity
Damper Height5-3/4"
Damper TypeStatic
Damper Width11-3/4"
Fire Rated1-1/2 hr.
For Duct ShapeRectangular
Frame Depth3 3/4"
Frame FinishGalvanized
Frame Less Flange72 sq. in.
Frame MaterialSteel
Frame Material Thickness22 ga.
Free Area0.3 sq. ft.
Fusible Link Temperature165 Deg. F
Material22 ga. Galvanized Steel
Max. Ambient Temp.165 Deg. F
Mounting LocationWall
Mounting PositionVertical
Mounting TypeStatic, Vertical
Nominal Duct Height6"
Nominal Duct Width12"
Overall Height5 3/4"
Overall Length3 3/4"
Overall Width11 3/4"
Product Datasheetdayton-2tga5.pdf
Recommended Retaining Angle2TGG8
Rough Opening ShapeRectangular
Rough Opening Width12"
ShapeRectangular
Switch ActionNormally Open

Shipping Info:

Ship weight (kg) 1.64
Ship height (cm)33.27
Ship length (cm)21.59
Ship width (cm)11.43
HS code8481809050
Country of OriginUS

Product Details:

Dayton 2TGA5 rectangular fire damper is employed in HVAC systems within commercial buildings and industrial facilities. They enhance fire safety by restricting the spread of flames and smoke through ventilation ducts during a fire emergency.

Features:

  • Dayton 2TGA5 rectangular fire damper features 22 gauge galvanised steel construction ensuring durability and resilience against fire-related hazards.
  • It has a fusible link that triggers at specific high temprature and closes shut using spring-loaded gates to prevent the spread of flames and smoke during a fire incident.
  • This fire damper is equipped with a gravity-based closure system that automatically shuts off airflow when exposed to high temperatures.
  • It is equipped with an extensive frame-less flange measuring 72 square inches, optimising airflow management within the ducts.

Compatible Accessories:

  • Dayton Vertical / Horizontal Retaining Angle: This retaining angle aids in secure installation, ensuring the optimal functioning of the fire damper in various mounting positions.
  • Dayton 2TGJ2 fusible link: It serves as a crucial component, triggering closure at elevated temperatures to enhance the damper's fire containment capabilities.

Frequently Asked Questions:

Q. At what temperature does the fusible link in this damper melt?

A. The fusible link melts at 165 degrees F, triggering the closure of the damper during a fire.

Q. What are the safety precautions to consider while using a fire damper?

A.

  • Conduct routine inspections to ensure the fire dampers is in proper working condition.
  • Adhere to applicable codes, standards, and regulations during installation and maintenance.
  • Only trained personnel should handle fire damper inspections, testing and repairs.
  • Maintain unobstructed access to the fire damper for inspections and maintenance.
  • Regularly test the automatic closing and manual override mechanisms.

Q. What are the differences between manual and automatic fire dampers?

A. Manual fire dampers and automatic fire dampers are both crucial components in fire protection systems, designed to prevent the spread of fire and smoke within buildings. While manual fire dampers require physical intervention for activation, typically through a mechanical lever or switch, automatic fire dampers operate autonomously in response to fire alarms, smoke detectors, or temperature sensors. The key distinction lies in their activation mechanisms: manual dampers demand human intervention, offering greater control but potentially slower response times, whereas automatic dampers offer quicker and automated reaction to fire-related cues, ensuring rapid containment of fire and smoke for enhanced safety.

Documentation:

Datasheet

Product Variants

ProductModelFor Duct ShapeFrame Less FlangeFree AreaMounting TypeOverall HeightRough Opening ShapeShapePrice
DAYTON 2TGA3 Rectangular Fire Damper 5-3/4 x 9-3/4 Inch | AC3GWV 2TGA3--0.219 sq. ft.Static, Vertical--Rectangular€74.81
DAYTON 2TGA6 Rectangular Fire Damper 7-3/4 x 11-3/4 Inch | AC3GWY 2TGA6--0.401 sq. ft.Static, Vertical--Rectangular€82.43
DAYTON 2TGA7 Rectangular Fire Damper 9-3/4 x 11-3/4 Inch | AC3GWZ 2TGA7--0.528 sq. ft.Static, Vertical--Rectangular€83.28
DAYTON 2TGA8 Fire Damper, 11-3/4 Inch Width, Rectangular | AC3GXA 2TGA8Square144 sq. in.0.7 sq. ft.Static, Vertical11 3/4"SquareSquare€116.84
DAYTON 2TGA9 Rectangular Fire Damper 11-3/4 x 13-3/4 In | AC3GXB 2TGA9--0.772 sq. ft.Static, Vertical--Rectangular€103.58
DAYTON 2TGC2 Rectangular Fire Damper 7-3/4 x 15-3/4 Inch | AC3GXD 2TGC2--0.561 sq. ft.Static, Vertical--Rectangular€88.80
DAYTON 2TGC3 Rectangular Fire Damper 11-3/4 x 15-3/4 In | AC3GXE 2TGC3--0.901 sq. ft.Static, Vertical--Rectangular€121.05

Explore Products

Contact us

Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 07:30 until 17:00.

DAYTON 2TGA5 Fire Damper, Static, 5-3/4 x 11-3/4 x 3-3/4 Inch Size, Vertical
€80.35 /unit