EATON G Series Molded Case Circuit Breaker Trip Units


Eaton G Series MCCB trip units are used in conjunction with the brand's G Series MCCBs for protecting circuits and equipment from overcurrents and short circuits. They are ideally used in distribution boards, switchgear and panel boards.

Filter
StyleModelMPNPrice
A
LT3250FA
LT3250FA€1,595.29
A
LT3400FA
LT3400FA€732.98
A
LT3500FA
LT3500FA€5,222.25
B
LT4250FA
LT4250FA€8,324.79
B
LT4400AA
LT4400AA€8,757.54
B
LT4500AA
LT4500AA€8,757.54
B
LT4600FA
LT4600FA€8,324.79
C
LT325035
LT325035€7,358.47
D
LT325035V
LT325035V€7,358.47
D
LT340035V
LT340035V€7,358.47
D
LT340036V
LT340036V€8,847.39
C
LT340038
LT340038€8,500.83
D
LT360035V
LT360035V€12,881.44
C
LT363033
LT363033€6,415.97
C
LT363038
LT363038€14,183.33
E
LT425032
LT425032€6,564.49
E
LT440035
LT440035€9,314.97
E
LT440036
LT440036€11,203.65
E
LT460033
LT460033€7,540.00
E
LT463032
LT463032€13,587.39
E
LT760032
LT760032€12,560.55
E
LT760033
LT760033€7,540.00

Features

  • They feature a modular design for easy integration into existing systems.
  • These trip units have an electronic LSI trip to prevent short circuits.
  • They come with LG frames that are HACR rated for use in refrigerators, heaters and air conditioners.

Frequently Asked Questions

What precautions should I consider when installing an Eaton G Series molded case circuit breaker?

To ensure safe and efficient operation, it is crucial to adhere to the manufacturer's instructions and select the appropriate size and type of Eaton G Series molded case circuit breaker for the intended application during installation. Additionally, proper wiring and grounding must be carried out.

What should I do if I detect a problem with my Eaton G Series molded case circuit breaker during maintenance or testing?

In the event of a problem being detected during maintenance or testing, it is recommended to take the circuit breaker out of service and perform repairs or replace it as needed.

How do I install these trip units?

  • Turn off the power supply.
  • Remove the circuit breaker cover.
  • Remove the existing trip unit.
  • Install the new trip unit.
  • Reconnect the wires.
  • Replace the circuit breaker cover.
  • Turn on the power supply and test the new trip unit.

How to maintain Eaton G Series MCCB trip units?

  • Inspect the trip unit for any signs of damage, corrosion, or wear and tear, and check that all connections are tight and secure.
  • Clean the trip unit using a soft, dry cloth or brush to remove any dirt, dust, or debris that may have accumulated over time.
  • Test the trip unit regularly to ensure that it is functioning correctly and can trip the circuit breaker as intended.