EATON DK Series Complete Molded Case Circuit Breakers, K Frame


Eaton DK Series complete MCCBs are used in motor control centres, switchboards, panelboards and busways to protect electrical systems from overcurrent and short circuit conditions.

Filter
StyleModelMPNPrice
A
DK2250
DK2250€5,901.66
A
DK2250W
DK2250W€5,895.28
A
DK2300
DK2300€3,241.66
A
DK2300S47
DK2300S47-
RFQ
A
DK2300V
DK2300V€6,150.33
A
DK2300W
DK2300W€6,366.45
A
DK2300X
DK2300X-
RFQ
A
DK2350
DK2350-
RFQ
A
DK2350V
DK2350V-
RFQ
A
DK2350W
DK2350W€5,895.28
A
DK2400
DK2400€2,778.56
A
DK2400C
DK2400C-
RFQ
A
DK2400D11
DK2400D11€5,967.01
A
DK2400H08
DK2400H08€5,868.17
A
DK2400KA05X07Y08
DK2400KA05X07Y08€6,673.24
A
DK2400KA06X07Y03
DK2400KA06X07Y03€6,022.81
A
DK2400KA06X07Y08
DK2400KA06X07Y08-
RFQ
A
DK2400W
DK2400W€6,366.45
A
DK2400Y
DK2400Y€6,037.16
B
DK3250
DK3250€2,778.56
B
DK3250C
DK3250C€7,425.71
B
DK3250H08
DK3250H08€7,049.48
B
DK3250S42
DK3250S42€9,381.76
B
DK3250V
DK3250V€7,390.62
B
DK3250W
DK3250W€2,778.56
B
DK3250WS42
DK3250WS42€8,879.58
B
DK3250Y
DK3250Y€7,272.65
B
DK3300B06
DK3300B06-
RFQ
B
DK3300C
DK3300C€7,403.38
B
DK3300H08
DK3300H08-
RFQ
B
DK3300S10
DK3300S10€9,078.85
B
DK3300S42
DK3300S42€9,078.85
B
DK3300V
DK3300V€7,038.28
B
DK3300W
DK3300W€2,778.56
B
DK3300WS10
DK3300WS10€8,720.16
B
DK3300X
DK3300X€6,872.51
B
DK3300Y
DK3300Y€7,272.65
B
DK3300Z01
DK3300Z01€7,390.62
B
DK3300Z15
DK3300Z15€7,390.62
C
DK3350
DK3350€2,778.56
B
DK3350VW
DK3350VW€7,046.28
B
DK3350W
DK3350W€2,778.56
B
DK3350WS42
DK3350WS42-
RFQ
B
DK3350X
DK3350X€6,872.51
B
DK3350Y
DK3350Y€7,272.65
B
DK3400A02
DK3400A02-
RFQ
B
DK3400H08
DK3400H08€8,138.31
B
DK3400S09
DK3400S09-
RFQ
B
DK3400S10
DK3400S10€9,086.83
B
DK3400U22
DK3400U22€9,078.85
B
DK3400V
DK3400V€2,907.47
B
DK3400W
DK3400W€2,459.64
B
DK3400WJ01
DK3400WJ01€8,425.24
B
DK3400WS10
DK3400WS10€8,720.16
B
DK3400WS32
DK3400WS32-
RFQ
B
DK3400WS42
DK3400WS42€8,313.65
B
DK3400X
DK3400X-
RFQ
B
DK3400XS10
DK3400XS10€8,911.46
B
DK3400Y
DK3400Y-
RFQ

Features

  • These MCCBs have 2 / 3 pole configurations for controlling multiple connections simultaneously.
  • They are equipped with a sliding switch with an On / Off function to identify the functioning of the circuit breaker.
  • These K-frame circuit breakers have a moulded case construction, which provides increased durability and protection against mechanical damage.
  • They are available in amperage ratings of 250, 350 and 400A.

Frequently Asked Questions

What are the reasons for frequent tripping of the circuit breaker?

Current overloads, short-circuits, ground fault surges, defective circuit breakers or an arc fault can cause tripping of the circuit breaker.

What are the points to inspect before operating the circuit breaker?

  • Keep the area around the breaker clean by using an enclosure. Remove the dust, dirt, grease, moisture, foreign contaminants or any safety hazards near the circuit breaker area.
  • Check that the unit's mechanical linkages, like the toggle actuator, are free to move by switching the unit On & Off several times.
  • Press the optional push-to-trip button at the bottom side of the unit to mechanically test the circuit breaker.
  • Inspect the unit for any cracks, chipping, discolouration or any sign of overheating. Tighten the terminals & connectors. Check the mounting hardware.

We are here to help!

Looking for a part not listed here?