EATON CHQ Series Thermal Magnetic Circuit Breakers
Eaton CHQ Series thermal magnetic circuit breakers are the classified replacement circuit breakers that replace & match the performance of original equipment breakers in commercial & light industrial electrical panels. They provide a reliable & cost-effective way to replace a breaker without replacing the entire electrical panel. These UL classified CHQ Series replacement breakers have been tested in Square D QO Series loadcenters for replacing Square D QO Series breakers. They h...ave an interrupt rating of 10kAIC.Read more
Style | Model | Number Of Poles | Circuit Breaker Type | Voltage | Price | |
---|---|---|---|---|---|---|
A | CHQ115CS | 1 | CH | 120/240V | - | RFQ
|
B | CHQ120 | 1 | CH | 120/240V | - | RFQ
|
C | CHQ140CS | 1 | CH | 120/240V | €90.91 | |
D | CHQ145 | 1 | CH | 120/240V | €82.07 | |
E | CHQ130 | 1 | CH | 120/240V | - | RFQ
|
F | CHQ140 | 1 | CH | 120/240V | €20.75 | |
A | CHQ115 | 1 | CH | 120/240V | €18.30 | |
G | CHQ130CS | 1 | CH | 120/240V | €95.52 | |
H | CHQ150CS | 1 | CH | 120/240V | - | RFQ
|
I | CHQ135 | 1 | CH | 120/240V | €73.71 | |
J | CHQ260 | 2 | CH | 120/240V | - | RFQ
|
K | CHQ235 | 2 | CH | 120/240V | €206.05 | |
L | CHQ225 | 2 | CH | 120/240V | €49.92 | |
M | CHQ250CS | 2 | CH | 120/240V | - | RFQ
|
N | CHQ220 | 2 | CH | 120/240V | €206.05 | |
O | CHQ220CS | 2 | CH | 120/240V | - | RFQ
|
P | CHQ250 | 2 | CH | 120/240V | €44.70 | |
Q | CHQ230CS | 2 | CH | 120/240V | - | RFQ
|
R | CHQ240 | 2 | CH | 120/240V | - | RFQ
|
S | CHQ230 | 2 | CH | 120/240V | €49.92 | |
T | CHQ240CS | 2 | CH | 120/240V | €218.45 | |
U | CHQ245 | 2 | CH | 120/240V | €49.92 |
Working Mechanism
- Eaton CHQ Series thermal magnetic circuit breakers use a trip mechanism to sense the current flowing through them.
- When the current exceeds the breaker's rated capacity, the trip mechanism triggers to open the circuit, interrupting the flow of electrical current and preventing further damage to the electrical system.
- They can be manually reset to quickly restore power to the circuit.
Frequently Asked Questions
What are the electrical ratings of these Eaton CHQ Series thermal magnetic circuit breakers?
They have current ratings ranging from 15 to 60A and a voltage rating of 120 / 240VAC.
How much space do these circuit breakers need in a loadcenter?
The single-pole Eaton CHQ Series thermal magnetic circuit breakers require one 3/4-inch (19.1 mm) space, whereas 2-pole circuit breakers, with a common trip, need two 3/4-inch spaces.
What wire size is required for connecting to these Eaton CHQ Series thermal magnetic circuit breakers?
They can be connected to a #14 to 8 AWG or two #14 to 10 AWG sized copper / aluminium wires.
We are here to help!
Looking for a part not listed here?
Explore More
- FENNER DRIVES
- HILMAN ROLLERS
- INTERTAPE
- KEYSHAFT
- BURRELL SCIENTIFIC
- Plate Casters
- Hole Saw Accessories
- Dust Collectors
- Foot Switches
- Brakes and Clutches
- 640 Series Straight Line Action Clamps - DESTACO
- Colour Coded Quick Connects, Female - OIL SAFE
- 97-100 Activarmr Medium Duty Oil Resistant Safety Gloves - ANSELL
- Cut Pro Ninja Force Cut Resistant Work Gloves - MCR SAFETY
- CP69 Series Impact Wrenches - CHICAGO PNEUMATIC
- Buna Gaskets - DIXON
- Ice/Water Dispensers - MANITOWOC
- Vertical-Lift MORSPEED Drum Stackers - MORSE DRUM
- Augers, Iwan-Type with T-Handle - HUMBOLDT
- WHEATON Polypropylene Vial Racks