EATON CHB Series Thermal Magnetic Circuit Breakers


Eaton CHB-Series thermal magnetic circuit breakers break the circuit in the event of short a circuits or overload.

Filter
Frame Type: CHB
StyleModelAIC RatingAmpsNumber of PolesVoltagePrice
A
CHB2100
-----
RFQ
B
CHB215ST
----€1,892.04
RFQ
C
CHB125
-251120V€107.76
D
CHB115GF
-201120/240V€295.49
B
CHB215
----€201.81
E
CHB220
----€201.81
F
CHB130
----€98.01
G
CHB115
----€98.01
H
CHB120
----€98.01
I
CHB210
-102120/240V€217.79
J
CHB230
-----
RFQ
A
CHB2110
----€1,134.21
K
CHB140
----€107.76
L
CHB270
-----
RFQ
M
CHB9T2
----€30.70
RFQ
N
CHB110
----€98.01
O
CHB170
----€401.56
RFQ
P
CHB160
----€213.76
RFQ
Q
CHB2125
----€1,134.21
R
CHB150
10kAIC@120V50A1120V€107.76
S
CHB240
10kAIC@240V40A2240V€222.44
T
CHB250
10kAIC@240V50A2240V€222.44
U
CHB290
10kAIC@240V90A2240V€846.96
V
CHB340
10kAIC@240V40A3240V€783.51
W
CHB3100
10kAIC@240V100A3240V€982.71
X
CHB260
10kAIC@240V60A2240V€222.44
Y
CHB3080
10kAIC@240V80A3240V€982.71
Z
CHB320
10kAIC@240V20A3240V€783.51
A1
CHB315
10kAIC@240V15A3240V€783.51
B1
CHB330
10kAIC@240V30A3240V€783.51
C1
CHB3090
10kAIC@240V90A3240V€982.71
D1
CHB350
10kAIC@240V50A3240V€783.51
E1
CHB360
10kAIC@240V60A3240V€783.51
F1
CHB370
10kAIC@240V70A3240V€846.96
G1
CHB280
10kAIC@240V80A2240V€783.51

Working Mechanism

  • In the normal state, these circuit breakers allow current to flow through the circuit.
  • In this case, the current-carrying contacts come into contact with one another.
  • When this device detects a ground fault, the contacts move apart and trip the circuit.

Features

  • Eaton CHB-Series thermal magnetic circuit breakers have standard box lug terminals to accommodate copper and aluminium wires of sizes 14 to 8 AWG.
  • Selected models have an internal common trip connection to operate all poles simultaneously.
  • They have a thermal-magnetic trip to avoid nuisance tripping during mild overloads but react instantly to severe short circuits.

Compatible Accessories

  • Eaton Load Centres: These units are useful for power distribution and circuit protection.

Standards and Approvals

  • UL

Frequently Asked Questions

What is the difference between a circuit breaker and a fuse?

A circuit breaker has an internal switch that trips when there is excess current, whereas a fuse is a metal piece that melts when the excess current overloads the circuit.

What is the interrupt rating of these circuit breakers?

10kAIC.

How to install these circuit breakers?

  • Remove the panel cover using a screwdriver.
  • Connect the neutral and ground wires.
  • Place the breaker inside and screw the cover back to the panel.

We are here to help!

Looking for a part not listed here?