EATON CHB Series Thermal Magnetic Circuit Breakers
Eaton CHB-Series thermal magnetic circuit breakers break the circuit in the event of short a circuits or overload.
Filter
Style | Model | Number Of Poles | Height | Wire Size | Voltage Rating | Circuit Breaker Type | Type | Price | |
---|---|---|---|---|---|---|---|---|---|
A | CHB9T2 | - | - | - | - | - | - | - | RFQ
|
B | CHB2125 | - | - | - | - | - | - | €1,251.92 | |
C | CHB140 | - | - | - | - | - | - | - | RFQ
|
D | CHB170 | - | - | - | - | - | - | €393.60 | |
E | CHB2110 | - | - | - | - | - | - | €1,251.92 | |
F | CHB160 | - | - | - | - | - | - | €210.22 | |
G | CHB270 | - | - | - | - | - | - | €455.38 | |
H | CHB215ST | - | - | - | - | - | - | €1,846.27 | |
E | CHB2100 | - | - | - | - | - | - | €680.94 | |
I | CHB125 | 1 | 3 2/5" | #14 AWG to 8 AWG | 120/240V | Chb | Circuit Breaker | €118.54 | |
J | CHB150 | 1 | 1 1/2" | #8 AWG to 4 AWG | 120/240V | Chb | Circuit Breaker | €118.54 | |
K | CHB115GF | 1 | 39" | #14 AWG to 8 AWG | 120/240V | Chb | Circuit Breaker | €279.38 | |
L | CHB115 | 1 | 3 1/5" | #14 AWG to 8 AWG | 120/240V | Chb | Circuit Breaker | €107.73 | |
M | CHB130 | 1 | 3 1/5" | #14 AWG to 8 AWG | 120/240V | Chb | Circuit Breaker | €107.73 | |
N | CHB120 | 1 | 4 2/5" | #14 AWG to 8 AWG | 120/240V | Chb | Circuit Breaker | €107.73 | |
O | CHB110 | 1 | 3.3" | #14 AWG to 8 AWG | 120/240V | Chb | Circuit Breaker | €107.73 | |
P | CHB260 | 2 | 2.7" | #8 AWG to 2 AWG | 120/240V | Chb | Circuit Breaker | €245.17 | |
Q | CHB230 | 2 | 3 2/5" | #14 AWG to 8 AWG | 120/240V | Chb | Circuit Breaker | €223.23 | |
R | CHB290 | 2 | 1 2/5" | #4 AWG to 1/0 AWG | 120/240V | Chb | Circuit Breaker | €943.45 | |
S | CHB240 | 2 | 3 2/5" | #8 AWG to 4 AWG | 120/240V | Chb | Circuit Breaker | €245.17 | |
T | CHB220 | 2 | 3 2/5" | #14 AWG to 8 AWG | 120/240V | Chb | Circuit Breaker | €223.23 | |
U | CHB280 | 2 | 1 2/5" | #4 AWG to 1/0 AWG | 120/240V | Chb | Circuit Breaker | €860.13 | |
V | CHB210 | 2 | 2 3/5" | #14 AWG to 8 AWG | 120/240V | Chb | Circuit Breaker | - | RFQ
|
H | CHB215 | 2 | 3 1/2" | #14 AWG to 8 AWG | 120/240V | Chb | Circuit Breaker | €223.23 | |
W | CHB250 | 2 | 1 4/5" | #8 AWG to 4 AWG | 120/240V | Chb | Circuit Breaker | €245.17 | |
X | CHB330 | 3 | 2.1" | #14 AWG to 8 AWG | 240V | Chb | Circuit Breaker | €860.13 | |
Y | CHB320 | 3 | 2" | #14 AWG to 8 AWG | 240V | Chb | Circuit Breaker | €860.13 | |
Z | CHB370 | 3 | 3.3" | #14 AWG to 8 AWG | 240V | Chb | Circuit Breaker | €943.45 | |
A1 | CHB3090 | 3 | 2 3/5" | #4 AWG to 1/0 AWG | 240V | Chb | Circuit Breaker | €1,071.25 | |
B1 | CHB360 | 3 | 3.3" | #8 AWG to 2 AWG | 240V | Chb | Circuit Breaker | €860.13 | |
C1 | CHB3100 | 3 | 2 1/5" | #4 AWG to 1/0 AWG | 240V | Chb | Circuit Breaker | €1,071.25 | |
D1 | CHB315 | 3 | 2.1" | #14 AWG to 8 AWG | 240V | Chb | Circuit Breaker | €860.13 | |
E1 | CHB340 | 3 | 3.3" | #8 AWG to 4 AWG | 240V | Chb | Circuit Breaker | €860.13 | |
F1 | CHB350 | 3 | 1/5" | #8 AWG to 4 AWG | 240V | Chb | Circuit Breaker | €819.17 | |
G1 | CHB3080 | 3 | 2" | #4 AWG to 1/0 AWG | 240V | Chb | Circuit Breaker | €1,071.25 |
Working Mechanism
- In the normal state, these circuit breakers allow current to flow through the circuit.
- In this case, the current-carrying contacts come into contact with one another.
- When this device detects a ground fault, the contacts move apart and trip the circuit.
Features
- Eaton CHB-Series thermal magnetic circuit breakers have standard box lug terminals to accommodate copper and aluminium wires of sizes 14 to 8 AWG.
- Selected models have an internal common trip connection to operate all poles simultaneously.
- They have a thermal-magnetic trip to avoid nuisance tripping during mild overloads but react instantly to severe short circuits.
Compatible Accessories
- Eaton Load Centres: These units are useful for power distribution and circuit protection.
Standards and Approvals
- UL
Frequently Asked Questions
What is the difference between a circuit breaker and a fuse?
A circuit breaker has an internal switch that trips when there is excess current, whereas a fuse is a metal piece that melts when the excess current overloads the circuit.
What is the interrupt rating of these circuit breakers?
10kAIC.
How to install these circuit breakers?
- Remove the panel cover using a screwdriver.
- Connect the neutral and ground wires.
- Place the breaker inside and screw the cover back to the panel.
We are here to help!
Looking for a part not listed here?
Explore More
- KEYSHAFT
- SMC VALVES
- WHITE LIGHTNING
- ALL MATERIAL HANDLING
- MERZ ELEKTRO
- Specialty Vises and Components
- Portable Coolers and Beverage Coolers
- Temporary Job Site Light Heads
- Rod Ends
- Insulated Pipe Covers
- Flex Impact Socket, 1/4 Inch Drive Size - PROTO
- Standard Work Gloves - CONDOR
- Fiberglass Adjustable Safety Cage Ladders - LITTLE GIANT LADDERS
- 330-M Series Pull Action Latch Clamps - DESTACO
- MAYHEW TOOLS Hollow Punches, SAE
- Additional Shelf - HALLOWELL
- Turn to Release Plastic Push Button Operator - SCHNEIDER ELECTRIC
- 316 Stainless Steel Inline Ball Valve, MNPT x Tube - HAM-LET
- Type C, Pillow Block, Split Tapered Roller Bearings - BALDOR / DODGE
- PX Explosion Proof Vibrators - VIBCO