EATON CCH Series Enclosed Breakers
Eaton CCH Series enclosed circuit breakers are ideal for preventing electrical damage to connected devices in commercial & industrial environments due to overloads or short circuits. These 3-pole circuit breakers protect equipment by automatically interrupting the flow of electricity to the circuit when a fault is detected. They can be reset once the fault has been resolved....Read more
Style | Model | Amps | Height | Type | Voltage | Wire Size | Number Of Poles | Price | |
---|---|---|---|---|---|---|---|---|---|
A | CCH3125SR01 | 125A | 1" | Enclosed Breakers | 240V | #2/0 AWG to 300 kcmil | 3 | €8,890.38 | |
A | CCH3150SR01 | 150A | 1" | Enclosed Breakers | 240V | #2/0 AWG to 300 kcmil | 3 | - | RFQ
|
A | CCH3200SR01 | 200A | 1" | Enclosed Breakers | 240V | #2/0 AWG to 300 kcmil | 3 | €8,890.38 | |
A | CCH3200SR24 | 200A | 1" | Enclosed Breakers | 240V | #2/0 AWG to 300 kcmil | 3 | €8,890.38 |
Features
- Eaton CCH Series enclosed circuit breakers are thermal magnetic, making them ideal to detect electric faults due to changes in temperature or magnetic field.
- These units are wired using #2/0 to 300 kcmil copper / aluminium wires for easy connection on panels.
- They have an enclosed design to house the trip unit & all current-carrying devices inside their thermal magnetic moulded case frame.
- These enclosed circuit breakers have a sliding handle with ON & OFF positions & current rating for easy identification of the breaker's status.
Compatible Accessories
- Eaton ECC Type Enclosures: These circuit breakers enclosures can house these 240V circuit breakers.
Standards and Approvals
- UL
- CSA
Frequently Asked Questions
What are the different performance ratings of these Eaton CCH Series enclosed circuit breakers?
Eaton CCH Series enclosed circuit breakers have a current rating ranging from 125 to 200A & a voltage rating of 240V.
What are the interrupt ratings of these Eaton CCH Series enclosed circuit breakers?
They have an interrupt rating of 100kAIC.
What is a shunt trip?
Eaton CCH Series enclosed circuit breakers feature a shunt trip device to mechanically trip the breaker remotely on applying power (from an external source) to their shunt trip terminals. They have a 120VAC or 24VDC shunt trip feature.
We are here to help!
Looking for a part not listed here?
Explore More
- ALC
- ELKAY
- KEYSHAFT
- PALMETTO PACKING
- SWITCH COMPONENTS
- Escape Hoods and Respirators
- Magnetic Drill Press Arbors and Adaptors
- Striping Marking Machine/Applicators
- Three Phase Transformers
- Ultrasonic Flow Meter Detector Accessories
- Flat Tip Bonded Neoprene Spindle Inch - DESTACO
- 6000 Series Heavy Duty Gasket Cutter Kits With Cutting Board - ALLPAX GASKET CUTTER SYSTEMS
- Mini Spout Lids - OIL SAFE
- Hoist Eye 360 Hoist Rings, Metric - ADB HOIST RINGS MFG.
- ANVIL 2139 Series Hexagonal Bushings, Forged Steel, Galvanized
- Flexible Extension 1/4 Drive Magentic - EAZYPOWER
- PVC Low Head PIP Orchard Risers, Saddle x Riser - SPEARS VALVES
- Brass Stems - AIR SYSTEMS INTERNATIONAL
- WI500 Series Medium Voltage Transformers, 3 Phase, 60Hz, 2.5kV & 5kV Class - ACME ELECTRIC
- Hanging Folded Chair & Table Storage Trucks - RAYMOND PRODUCTS