EATON C Series Molded Case Circuit Breaker Trip Units, K Frame
Eaton C Series moulded case circuit breaker trip units open the circuit during thermal overload, short circuit or ground fault. They are used in conjunction with circuit breakers to detect faults and trip the breaker. These trip units are available in thermal-magnetic and electronic LSI variant...s.Read more
Filter
Style | Model | MPN | Price | |
---|---|---|---|---|
A | KES3125LSGB22 | KES3125LSGB22 | €7,630.11 | |
A | KES3125LSIGB21 | KES3125LSIGB21 | €9,828.40 | |
B | KES3250ALSIGB20 | KES3250ALSIGB20 | €13,066.63 | |
B | KES3250ALSIGB22ZG | KES3250ALSIGB22ZG | €13,029.96 | |
B | KES3250ALSIZG | KES3250ALSIZG | €8,739.21 | |
B | KES3250LSGB21 | KES3250LSGB21 | €8,267.97 | |
B | KES3250LSI | KES3250LSI | - | RFQ
|
B | KES3250LSIGZG | KES3250LSIGZG | €9,580.86 | |
B | KES3400ALSI | KES3400ALSI | €7,987.40 | |
B | KES3400ALSIG | KES3400ALSIG | €11,836.26 | |
B | KES3400ALSIGZG | KES3400ALSIGZG | €12,588.05 | |
B | KES3400LSIGB22 | KES3400LSIGB22 | €9,270.97 | |
C | KT2200TV | KT2200TV | €1,655.79 | |
C | KT2400T | KT2400T | €706.02 | |
D | KT3150TV | KT3150TV | €1,982.18 | |
D | KT3350T | KT3350T | €977.77 | |
D | KT3400T | KT3400T | €977.77 | |
D | KT3400TA | KT3400TA | €2,475.44 | |
D | KT3400TJ01 | KT3400TJ01 | €2,365.43 | |
D | KT3400TV | KT3400TV | €1,982.18 | |
E | KT4250T | KT4250T | €3,296.92 | |
E | KT4315T | KT4315T | €3,296.92 | |
A | KWS4125LSI6 | KWS4125LSI6 | €8,643.85 | |
A | KWS4250LSI6 | KWS4250LSI6 | €8,643.85 |
Working Mechanism
Thermal-magnetic Trip Units:
- Thermal-magnetic trip units consist of a thermal and a magnetic element to detect faults.
- When the temperature of the circuit breaker exceeds a certain threshold due to a fault or other problem, the thermal element trips and interrupts the flow of current.
- When the current flowing through the circuit breaker exceeds its interrupt rating, the magnetic element trips and interrupts the current flow.
Electronic Trip Units:
- These units use zone selective interlocking to establish a communication scheme to connect line and load breaker trip units.
- When a fault occurs, the trip units communicate to determine which load-side breaker is closest to the fault.
- The trip unit in the breaker closest to the fault overrides any customer-defined delay and opens instantaneously.
- It clears the fault and allows line-side breakers to remain closed.
Frequently Asked Questions
What type of circuit breaker configuration can this trip unit be installed on?
These trip units can be installed on two-pole, three-pole and four-pole circuit breakers.
How do you reset a trip unit?
- Locate the circuit breaker that has tripped and switch it off.
- Once the circuit breaker is off, switch it back on to reset the trip unit.
We are here to help!
Looking for a part not listed here?
Popular Search Queries
Explore More
- BLACK & DECKER
- KELCH
- KEYSHAFT
- VENTAMATIC
- TRIUMPH TWIST DRILL
- Bench Grinders
- Grease Fittings
- Pry Bar Lever Dollies
- Gouging Electrodes
- Lighting Dimmer Accessories
- 30240 Akrobins Plastic Storage Bins - AKRO-MILS
- TS-PROBES Series Digital Temperature Switch Probes - DWYER INSTRUMENTS
- HashMark Master - NEWSTRIPE
- 2001 Chemical Resistant Pump Tubings - TYGON
- Powerline X4200 Gas Springs - ASSOCIATED SPRING RAYMOND
- Minblade Series Fuses Holders - BATTERY DOCTOR
- Interchange Hydraulic Filters, Glass, 5 Micron - MAIN FILTER INC.
- CPVC True Union 2000 Industrial 3-Way Horizontal Diverter Ball Valves, DIN Socket, EPDM, Metric - SPEARS VALVES
- EL Series, BMQ-D Style, 821 Size, Aluminium Worm Gear Reducers - GROVE GEAR
- Keyed Different Standard Shackle Padlocks - MASTER