Item | Data-Logger |
Ac Adapter | Battery Powered |
Ac Voltage Accuracy | Not Applicable |
Alert Type | Digital Display, Sound |
Amps Accuracy | Not Applicable |
Battery Chemistry | Lithium |
Battery Voltage | 3V |
Calibration Certificate | Available Separately , Yes |
Cat Safety Rating | Not Applicable |
Current Channels | Not Applicable |
Dc Current Accuracy | Not Applicable |
Dc Voltage Accuracy | Not Applicable |
Digital Readout | LCD |
Features | Adjustable Alarm, For Monitoring Material During Transportation, Integrates With Maxithermal Software |
Height | 2" |
Max. Dc Voltage Measured | Not Applicable |
Max. Operating Temp. | Not Applicable |
Max. Pressure Measured | Not Applicable |
Max. Relative Humidity Measured | 100% |
Maximum Ac Current | Not Applicable |
Maximum Ac Voltage Measured | Not Applicable |
Maximum Dc Current Measurement | Not Applicable |
Maximum Dew Point Measured | Not Applicable |
Min. Amps Measurement | Not Applicable |
Min. Dc Voltage Measured | Not Applicable |
Minimum Ac Voltage Measured | Not Applicable |
Minimum Dew Point Measured | Not Applicable |
Minimum Operating Temperature Degrees F | Not Applicable |
Minimum Sampling Rate | Not Applicable |
No. Of Batteries Required | 1 |
No. Of Voltage Channels | Not Applicable |
Overall Depth | 1 1/8" |
Overall Height | 3 1/2" |
Overall Width | 2" |
Parameters Measured | Relative Humidity, Temperature Degrees C |
Power Source | Battery |
Relative Humidity Range | 0% to 100% |
Remote Probe | No |
Resistance Properties | Water Resistant |
Sample Point Storage | 7680 Data Points |
Software Options | Software Included |
Software Required | No |
Special Features | Duration Of Temperature Excursion, User Selectable Quarantine Notification, User-Defined Recording Intervals |
Temp. Range | -29°C to +72°C |
Time Intervals | 2 sec. to 2 Months |
Voltage Range | 3V |
Width | 3 1/2" |
Accuracy °c | +/-0.2° |
Batteries Included | Yes |
Battery Run Time | 2 yrs. |
Calibration Certificate Type | Available Separately |
Compatible Operating Systems | Windows 7, WindowsVista, Windows XP |
Data Logger Type | Humidity, Temperature |
Digital Display Screen Type | LCD |
Interface | USB |
Manufacturer Warranty Length | 1 yr. |
Maximum Relative Humidity Measured | 100% |
Maximum Sampling Rate | 30 Days |
Maximum Temperature Measured °c | 72°C |
Maximum Temperature Measured °f | 161°F |
Minimum Relative Humidity Measured | 0% |
Minimum Temperature Measured °c | -29°C |
Minimum Temperature Measured °f | -20.2°F |
Number Of Batteries Required | 1 |
Number Of Probes Included | 0 |
Number Of Records Stored | 7680 |
Relative Humidity Measured | 0 % to 100 % |
Temperature Measured °c | -29°C to 72°C |
Temperature Measured °f | -20.2°F to +161°F |