KMC CONTROLS BAC-4221CW0001 Controller Bacnet Fan Coil Units | AF9EFZ 29VK42

KMC CONTROLS BAC-4221CW0001 Controller Bacnet Fan Coil Units

Item: AF9EFZModel: BAC-4221CW0001Cross Ref: 29VK42
Limited Availability

Get it by Tuesday, Jun 17

Request a Quote

Payment

Product Specifications:

ItemController
Amps1A
Backlit ScreenYes
Backlit TypeMotion Activated
ConnectionScrew Terminals
Connection TypeScrew Terminals
Dehumidification ControlYes
Dimensions1" x 1.047"
Display TypeDigital
Dual Transformer CompatibleYes
Electrical Connection TypeHardwired
Enclosure ColorWhite
For Use WithFan Coil Units
Housing ColorWhite
Housing MaterialPlastic
Housing TypeFlame Retardent Housing
Humidification ControlYes
IncludesBackplate
InputsThermistors Type II Or III
Maximum Operating Humidity100%
Mounting DirectionHorizontal
Number Of Cooling Stages (conventional System)1
Number Of Cooling Stages (heat Pump System)1
Number Of Heating Stages (conventional System)1
Number Of Heating Stages (heat Pump System)1
Number Of Poles1
Number Of Relay Control Output6
Number Of Relay Inputs0
Number Of Relay Inputs/outputs0
Occupancy SensorIncludes Onboard Occupancy Sensor
Overall Depth1 1/8"
Overall Height5 1/8"
Overall Width3 1/2"
Remote Control FunctionsTemperature Control
Screen Height1 1/16"
Screen Width1"
Sensor Length33 ft.
Sensor LocationRemote
Sensor TypeThermistor
Temp. Sensitivity-0.36°F to +0.36°F
Thermostat TypeLow Voltage
TypeBacnet
Voltage24V AC
WirelessHardwired
Amperage1A
ApplicationHeat Or Cool
Compatible System TypeFan Coil Units
Contact Rating24V AC
Control OutputSingle Stage RTU/Heat Pump with Economizer, Two Stage RTU/Heat Pump with Economizer
Control TypePush Button
Frequency50/60 Hz
Humidification/dehumidification ControlYes
Key FeaturesOn/Off Valves, Three Speed Fan
Lead Wire Gauge14 ga., 22 ga.
Maximum Operating Temperature140°F
Minimum Operating Humidity0%
Minimum Operating Temperature32°F
Mounting LocationWall
Network Protocol CompatibilityBACnet MS/TP
Number Of Cooling Stages - Conventional System1
Number Of Cooling Stages - Heat Pump System1
Number Of Heating Stages - Conventional System1
Number Of Heating Stages - Heat Pump System1
Number Of Pipes2, 4
Number Of Relay Outputs6
StandardsANSI/ASHRAE BACNET STANDARD 135-2008, BACNET TESTING LABORATORY LISTED, FCC CLASS A, PART 15, SUBPART B AND COMPLIES WITH CANADIAN ICES-003 CLASS B, SASO PCP REGISTRATION KSA R-103260, UL 916 ENERGY MANAGEMENT EQUIPMENT
Switch TypeSPST
Temperature AdjustmentOn/Off
Temperature ScaleFahrenheit/Celsius
Temperature Sensitivity+/-0.36°F
Terminal Designations-A, +B, AO6, AO7, AO8, BO5, COM, DAT, FAN-H, FAN-L, FAN-M, GND, RBO4, RS, WST

Shipping Info:

Ship weight (kg) 0.21
Ship height (cm)5.08
Ship length (cm)15.24
Ship width (cm)13.65
HS code9017900136

Product Variants

ProductModelPrice
KMC CONTROLS BAC-4001CW0001 Controller Bacnet Fan Coil Units | AF9EEN 29VK18 BAC-4001CW0001€582.80
KMC CONTROLS BAC-4001CW0002 Controller Bacnet Rooftop Units Split | AF9EEP 29VK19 BAC-4001CW0002€561.98
KMC CONTROLS BAC-4001CW0003 Controller Bacnet Heat Pump Units | AF9EEQ 29VK20 BAC-4001CW0003€561.98
KMC CONTROLS BAC-4002CW0001 Controller Bacnet Fan Coil Units | AF9EER 29VK21 BAC-4002CW0001€561.98
KMC CONTROLS BAC-4003CW0002 Controller Bacnet Rooftop Units Split | AF9EET 29VK22 BAC-4003CW0002€618.46
KMC CONTROLS BAC-4003CW0003 Controller Bacnet Heat Pump Units | AF9EEU 29VK23 BAC-4003CW0003€618.46
KMC CONTROLS BAC-4007CW0001 Controller Bacnet Fan Coil Units | AF9EEV 29VK24 BAC-4007CW0001€561.98

Explore Products

Contact us

Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 07:30 until 17:00.

KMC CONTROLS BAC-4221CW0001 Controller Bacnet Fan Coil Units