Item | Clamp Meter |
Ac Current Accuracy | 2% |
Ac Response | TRMS |
Audible Continuity | Yes |
Auto Power Off | Yes |
Battery Type | AAA |
Calibration Certificate | Available Separately |
Calibration Frequency | 50/60 Hz |
Capacitance | 62 µF |
Counts | 6000 |
Data Hold | Yes |
Data Storage | Yes |
Display | Backlit LCD |
Frequency Counter | 60 kHz |
Jaw Style | Clamp On |
Max. Ac Voltage | 600V AC |
Max. Amps | 60A |
Max. Conductor Size | 300 mcm |
Max. Dc Amps | 60A |
Max. Dc Voltage | 600V |
Operating Temp. | +32°F to +104°F , +32°F to +113°F |
Peak Hold | No |
Ac Current Measurement Resolution | 0.1 mA |
Ac Response Calculation | TRMS |
Ac Voltage Measurement Resolution | 1 mV |
Auto Ranging | Yes |
Bar Graph Included | No |
Basic Ac Current Accuracy | -2.5% to +2.5% |
Basic Ac Voltage Accuracy | +/-1% |
Basic Dc Current Accuracy | +/-2% |
Basic Dc Voltage Accuracy | +/-0.70% |
Batteries Included | Yes |
Battery Access | Yes |
Battery Size | AAA |
Bluetooth Compatible | No |
Calibration Certificate Included | No |
Capacitance Measurement Accuracy | ±10% |
Capacitance Measurement Resolution | 1 pF |
Current Leakage Testing | No |
Data Logging | Yes |
Dc Current Measurement Resolution | 1 mA |
Dc Voltage Measurement Resolution | 0.1 mV |
Diode Test | Yes |
Display Type | Backlit LCD |
Dustproof | No |
Frequency Measurement Accuracy | +/-0.1% |
Frequency Measurement Resolution | 0.001 Hz |
Includes | (2) AAA Batteries, Carrying Case, Test Leads |
Inrush | No |
Instrument Counts | 6000 |
Intrinsically Safe | No |
Jaw Opening | 0.7" |
Manufacturers Warranty Length | 2 yrs. |
Max. Ac Current | 1000A |
Max. Dc Current | 60A |
Max. Resistance | 60 M ohms |
Maximum Capacitance Measurement | 62 mF |
Maximum Conductor Size | 300 MCM |
Maximum Frequency Measurement | 60 kHz |
Maximum Operating Temperature | 104°F |
Maximum Storage Temperature | 122°F |
Minimum Ac Current Measurement | 600 mA |
Minimum Ac Voltage Measurement | 6V |
Minimum Capacitance Measurement | 6.2NF |
Minimum Dc Current Measurement | 6A |
Minimum Frequency Measurement | 10 Hz |
Minimum Operating Temperature | 32°F |
Minimum Resistance Measurement | 600 ohms |
Non-contact Voltage Detector | Yes |
Overall Height | 1.3" |
Overall Width | 2 2/5" |
Parameters Measured | AC Voltage, DC Voltage, AC Current, DC Current, Capacitance, Continuity, Diode, Frequency, Inrush AC Current, Resistance |
Removable Screen | No |
Resistance Measurement Accuracy | +/-1.50% |
Resistance Measurement Resolution | 0.1 ohm |
Safety Rating | Cat II 600V, Cat III 300V |
Standards | CE, CULUS |
Thermal Imaging | No |
Waterproof | No |