Control Type: Keypad/Remote , Digital Readout: Yes , Input Frequency: 50/60 Hz , Input Voltage: 200-230 VAC , Key Pad Lockout: Yes
Style | Model | Protection | Depth | Display Type | Starting Torque | Width | Enclosure | Height | Max. HP | Price | |
---|---|---|---|---|---|---|---|---|---|---|---|
A | FRN007F1S-2U | Over breaking, Overvoltage, Under voltage, Motor Thermal Overload, Drive Thermal Overload, Phase to Phase or Phase to Ground Short Circuit, Phase Failure | 8.46" | LED | 200% | 8.66" | NEMA 1 | 10.24" | 7.5 | €965.17 | |
A | FRN030F1S-2U | Over breaking, Overvoltage, Under voltage, Motor Thermal Overload, Drive Thermal Overload, Phase to Phase or Phase to Ground Short Circuit, Phase Failure | 8.46" | LED | 200% | 9.84" | NEMA 1 | 15.75" | 30 | €2,660.63 | |
A | FRN040F1S-2U | Over breaking, Overvoltage, Under voltage, Motor Thermal Overload, Drive Thermal Overload, Phase to Phase or Phase to Ground Short Circuit, Phase Failure | 10.04" | LED | 200% | 12.6" | NEMA 1 | 21.65" | 40 | €3,348.21 | |
A | FRN005F1S-2U | Over breaking, Overvoltage, Under voltage, Motor Thermal Overload, Drive Thermal Overload, Phase to Phase or Phase to Ground Short Circuit, Phase Failure | 6.42" | LED | 200% | 5.91" | NEMA 1 | 10.24" | 5 | €846.43 | |
B | FRN007P11W-2UX | Overload, Overvoltage, Under voltage, Input phase loss, Overheating, Short-circuit, Ground fault, Motor overload, DB resistor overheating, Stall prevention, Output phase loss, Motor protection by PTC thermistor, Auto reset | 7.68" | LED, LCD | 50% | 8.66" | IP40/NEMA 1 | 10.24" | 7.5 | €2,507.11 | |
B | FRN003G11W-2UX | Overload, Overvoltage, Under voltage, Input phase loss, Overheating, Short-circuit, Ground fault, Motor overload, DB resistor overheating, Stall prevention, Output phase loss, Motor protection by PTC thermistor, Auto reset | 5.71" | LED, LCD | 200% | 5.91" | NEMA 4 | 10.24" | 3 | €2,096.18 | |
C | FRN0020C2S-2U | Overvoltage, Overcurrent, Incoming surge, Under voltage, Input phase loss, Output phase loss, Overheating, Overload | 5.47" | LED | - | 5.51" | IP20 | 7.09" | 5 | €534.86 |
We are here to help!
Looking for a part not listed here?
Explore More
- Coring Bits
- Hydraulic Manual Stack Valve Systems
- Fiberglass Work Platforms
- Flywheel
- Aluminum Tubing
- Dust Mops Dusters and Cleaning Pads
- Push Buttons
- Solar Panels and Accessories
- Central Equipment
- Springs
- OMRON PNP Photoelectric Sensor
- WESTWARD Flaring Tool
- DAZOR 15-watt Linear Fluorescent
- AUTONICS Lcd Counter/totalizer Digital 8 Digits
- DIXON Beveled Stems
- VULCAN HART Final Assembly
- SOUTHWIRE COMPANY Ultratite Series Flexible Non-Metallic Liquid Tight Conduit
- SPEARS VALVES PVC Gate Valves, Socket Ends, Buna
- LEWISBINS Unit Dose Bins
- SMC VALVES Wear Ring