EATON FD Series Complete Molded Case Circuit Breakers, F Frame


Eaton Series C molded case circuit breakers reduce risks of damage by fault currents and fatal electrical shocks.

Filter
StyleModelMPNPrice
A
ELFD3030LA06
ELFD3030LA06-
RFQ
B
FD1010
FD1010€448.95
C
FD1010L
FD1010L€449.97
D
FD1015
FD1015€448.95
C
FD1015L
FD1015L€470.21
C
FD1015LBP10
FD1015LBP10-
RFQ
B
FD1015VL
FD1015VL€495.06
B
FD1020B15
FD1020B15€844.77
B
FD1020BP10
FD1020BP10€953.51
B
FD1020H01
FD1020H01€516.04
B
FD1020J01
FD1020J01-
RFQ
B
FD1020J01BP10
FD1020J01BP10-
RFQ
C
FD1020L
FD1020L€465.55
C
FD1020LBP10
FD1020LBP10€447.65
B
FD1025
FD1025-
RFQ
C
FD1025L
FD1025L€449.97
E
FD1030BP10
FD1030BP10-
RFQ
B
FD1030L
FD1030L€470.21
B
FD1030LBP10
FD1030LBP10€472.85
B
FD1035
FD1035€492.95
C
FD1035L
FD1035L-
RFQ
D
FD1040
FD1040€519.98
C
FD1040L
FD1040L-
RFQ
B
FD1045
FD1045€448.43
C
FD1045L
FD1045L-
RFQ
B
FD1050
FD1050€537.55
C
FD1050L
FD1050L€465.55
B
FD1060
FD1060€537.55
C
FD1060L
FD1060L€449.97
B
FD1070
FD1070€523.82
C
FD1070L
FD1070L€503.60
B
FD1080
FD1080€501.27
C
FD1080L
FD1080L-
RFQ
B
FD1090
FD1090-
RFQ
C
FD1090L
FD1090L€503.60
B
FD1100
FD1100€551.05
C
FD1100L
FD1100L-
RFQ
B
FD1110
FD1110-
RFQ
B
FD1125
FD1125€1,247.32
C
FD1125L
FD1125L€1,150.20
B
FD1150
FD1150€1,247.32
B
FD1150B15
FD1150B15-
RFQ
C
FD1150L
FD1150L€1,150.20
C
FD1150LM01
FD1150LM01€1,110.57
F
FD2015L
FD2015L€1,149.06
F
FD2015LA06
FD2015LA06-
RFQ
F
FD2015LM03
FD2015LM03€1,076.37
F
FD2015VL
FD2015VL€1,071.72
F
FD2020A06
FD2020A06€1,445.53
F
FD2020B06
FD2020B06€1,488.27
F
FD2020H08
FD2020H08€1,218.58
F
FD2020L
FD2020L€1,149.06
F
FD2020LA08
FD2020LA08€1,449.42
F
FD2020LA13
FD2020LA13€1,731.52
F
FD2020LM03
FD2020LM03€1,076.37
F
FD2020S22
FD2020S22€1,856.63
F
FD2020VL
FD2020VL€1,117.57
F
FD2025L
FD2025L€1,110.57
F
FD2030A06
FD2030A06-
RFQ
F
FD2030B06
FD2030B06€1,488.27
F
FD2030H08
FD2030H08€1,218.58

Working Mechanism

  • Eaton molded case circuit breakers are equipped with fixed thermal and fixed magnetic trips.
  • The thermal trip comprises a bi-metallic strip that gets heated when an overcurrent passes through the conductors, causing the contacts to open and interrupt the current flow.
  • The magnetic trip, on the other hand, has an electromagnetic component that detects the presence of a short circuit.
  • As the current rises abruptly, a magnetic field is created that causes the displacement in the tripping coil.
  • This opens the contact again and stops the current flow, preventing any further damage to the equipment.

Features

  • These circuit breakers feature a non-interchangeable, thermal-magnetic trip that avoids nuisance tripping on mild overloads while reacting instantly when exposed to faulty currents, thus providing maximum protection.
  • They feature a contact design that offers high-speed blow-open action, resulting in superior performance and eliminating the risk of potential hazards.
  • These FD Series complete MCCBs come with an enhanced, easy-to-use interface, allowing the operator to view and make adjustments to the trip settings.
  • They are integrated with load-side terminals for easy installation with panelboards and load centres.

Standards and Approvals

  • UL

Frequently Asked Questions

How to maintain the frame of these molded case circuit breakers?

  • Inspect the frame regularly for any signs of damage or wear like cracks, chips or corrosion.
  • Use a soft brush or cloth to remove any dirt, dust or debris from the frame.
  • Always lubricate moving parts of the frame including hinges or latches to ensure smooth operation.

What is the function of molded cases?

Molded cases hold current-carrying components, trip devices and mechanisms integrated into one unit.

We are here to help!

Looking for a part not listed here?