EATON FD Series Complete Molded Case Circuit Breakers, F Frame


Eaton Series C molded case circuit breakers reduce risks of damage by fault currents and fatal electrical shocks.

Filter
AIC Rating: 35kAIC@480V , Frame Type: FD
StyleModelAmpsNumber of PolesVoltagePrice
A
FD2035LA08H08
---€3,778.72
RFQ
B
FD3125S02
---€9,591.69
RFQ
A
FD2025L
---€2,607.97
RFQ
A
FD2020L
----
RFQ
B
FD3040V
---€3,045.55
RFQ
B
FD3040LM04
---€3,100.00
RFQ
B
FD3040L
---€3,059.15
RFQ
B
FD3150A02
---€8,627.07
RFQ
B
FD3035V
---€3,045.55
RFQ
B
FD3040BP10
---€2,899.68
RFQ
B
FD3150A14S08
---€11,017.23
RFQ
B
FD3040J01
---€3,646.48
RFQ
B
FD3040H01
---€3,628.97
RFQ
C
FD3030VSH09
---€3,551.18
RFQ
A
FD2030L
---€2,607.97
RFQ
B
FD3125U82
---€9,299.98
RFQ
C
FD3030LM04
---€3,100.00
RFQ
B
FD3150A09S23
---€10,637.99
RFQ
C
FD3030L
----
RFQ
B
FD3125VW
---€7,683.86
RFQ
C
FD3030J01F01H08
---€4,533.29
RFQ
C
FD3030V
---€3,045.55
RFQ
C
FD3030BP10
---€2,899.68
RFQ
B
FD3025VSH09
---€3,551.18
RFQ
B
FD3125M04
---€7,456.32
RFQ
B
FD3025V
---€3,045.55
RFQ
B
FD3125S05
---€9,607.25
RFQ
A
FD2030H08
---€2,862.72
RFQ
A
FD2035
---€687.18
B
FD3125A10
---€8,998.52
RFQ
D
ELFD3030LA06
---€8,531.78
RFQ
E
FD1020L
----
RFQ
A
FD2175LS21
---€8,652.36
RFQ
F
FD1020J01BP10
---€1,260.23
RFQ
A
FD2150LF01V4
---€9,371.92
RFQ
F
FD1010
---€406.97
A
FD2125LSA06
---€7,337.67
RFQ
E
FD1015LBP10
---€1,056.03
RFQ
A
FD2125L
---€6,711.45
RFQ
F
FD1015VL
---€1,162.98
RFQ
F
FD1020B15
---€1,983.68
RFQ
F
FD1020H01
---€1,211.60
RFQ
A
FD2100L
---€3,045.55
RFQ
A
FD2030VL
---€2,607.97
RFQ
A
FD2100C05
---€4,482.74
RFQ
A
FD2080L
---€3,045.55
RFQ
A
FD2070V
---€2,994.98
RFQ
A
FD2060W01V4
---€3,430.60
RFQ
A
FD2060LF01V4
---€3,646.48
RFQ
A
FD2060S22
---€4,362.16
RFQ
A
FD2060F01V4
---€3,619.25
RFQ
A
FD2050L
----
RFQ
A
FD2050S22
---€4,362.16
RFQ
A
FD2050C05
---€3,395.60
RFQ
A
FD2040L
---€2,607.97
RFQ
A
FD2045
---€687.18
G
FD4070L
---€1,654.30
B
FD3020BP10
---€2,899.68
RFQ
F
FD1030LBP10
---€1,056.03
RFQ
B
FD3070BP10
---€3,418.93
RFQ
A
FD2015LA06
---€3,510.34
RFQ

Working Mechanism

  • Eaton molded case circuit breakers are equipped with fixed thermal and fixed magnetic trips.
  • The thermal trip comprises a bi-metallic strip that gets heated when an overcurrent passes through the conductors, causing the contacts to open and interrupt the current flow.
  • The magnetic trip, on the other hand, has an electromagnetic component that detects the presence of a short circuit.
  • As the current rises abruptly, a magnetic field is created that causes the displacement in the tripping coil.
  • This opens the contact again and stops the current flow, preventing any further damage to the equipment.

Features

  • These circuit breakers feature a non-interchangeable, thermal-magnetic trip that avoids nuisance tripping on mild overloads while reacting instantly when exposed to faulty currents, thus providing maximum protection.
  • They feature a contact design that offers high-speed blow-open action, resulting in superior performance and eliminating the risk of potential hazards.
  • These FD Series complete MCCBs come with an enhanced, easy-to-use interface, allowing the operator to view and make adjustments to the trip settings.
  • They are integrated with load-side terminals for easy installation with panelboards and load centres.

Standards and Approvals

  • UL

Frequently Asked Questions

How to maintain the frame of these molded case circuit breakers?

  • Inspect the frame regularly for any signs of damage or wear like cracks, chips or corrosion.
  • Use a soft brush or cloth to remove any dirt, dust or debris from the frame.
  • Always lubricate moving parts of the frame including hinges or latches to ensure smooth operation.

What is the function of molded cases?

Molded cases hold current-carrying components, trip devices and mechanisms integrated into one unit.

We are here to help!

Looking for a part not listed here?