EATON EGHDC Series DC Circuit Breakers
Eaton EGDC-Series DC circuit breakers are compact, high-performance circuit breakers designed to protect DC electrical systems and equipment from overloads, short circuits and ground faults.
Filter
Style | Model | Price | |
---|---|---|---|
A | EGHDC3080FFW | €2,991.09 | RFQ
|
A | EGHDC3040FFG | €2,473.78 | RFQ
|
A | EGHDC3090FFG | €3,022.19 | RFQ
|
A | EGHDC3045FFW | €2,440.70 | RFQ
|
A | EGHDC3060FFW | €2,440.70 | RFQ
|
A | EGHDC3050FFW | €2,440.70 | RFQ
|
A | EGHDC3040FFW | €2,440.70 | RFQ
|
A | EGHDC3045FFG | €2,473.78 | RFQ
|
A | EGHDC3035FFW | €2,440.70 | RFQ
|
A | EGHDC3080FFG | €3,022.19 | RFQ
|
A | EGHDC3035FFG | €2,473.78 | RFQ
|
A | EGHDC3070FFW | €2,991.09 | RFQ
|
A | EGHDC3025FFW | €2,440.70 | RFQ
|
A | EGHDC3030FFW | €2,440.70 | RFQ
|
A | EGHDC3030FFG | €2,473.78 | RFQ
|
A | EGHDC3025FFG | €2,473.78 | RFQ
|
A | EGHDC3100FFG | €3,022.19 | RFQ
|
A | EGHDC3050FFG | €2,473.78 | RFQ
|
A | EGHDC3090FFW | €2,991.09 | RFQ
|
A | EGHDC3060FFG | €2,473.78 | RFQ
|
A | EGHDC3070FFG | €3,022.19 | RFQ
|
A | EGHDC3100FFW | €2,991.09 | RFQ
|
Features
- These circuit breakers can withstand extreme ambient temperatures ranging from -40 to 70 degrees C.
- They can be applied in grounded or ungrounded systems.
- These fixed thermal fixed magnetic breakers have line & load terminals for improved performance.
- They are available in current & voltage ratings of 150A, 750VDC; 3000A, 600VDC and 600A, 1000VDC.
Standards and Approvals
- UL
Frequently Asked Questions
What are the interrupt ratings of these circuit breakers?
- 100kAIC at 240VAC
- 35kAIC at 600Y/347VAC
- 65kAIC at 480VAC
How to install Eaton EGDC-Series DC circuit breakers?
- Inspect the circuit breaker.
- Install the interphase barriers and terminals.
- Mount the circuit breaker to its intended location.
- Connect line and load conductors to the circuit breaker.
- Torque terminals to the manufacturer's recommended values.
- Attach terminal shields if required.
- Check mounting hardware for correct torque loading.
- Check terminal connecting hardware for correct torque loading.
- Install secondary cover with screws.
- Test the circuit breaker to ensure proper function.
We are here to help!
Looking for a part not listed here?
Explore More
- Fuel Caddies
- Scribers and Probes
- Film and Seal Dispensers
- Gas Fired Duct Furnaces
- Flexible Strip Heaters
- Hydraulic System Components
- DC Motors
- Waste Disposers
- Valve Actuators Enclosures and Accessories
- Alloy Steel
- USA SEALING Silicone Flange Gasket, 5-7/8 Inch Outside Diameter
- KETT TOOLS Eccentric Bushings
- ANVIL Pre Galvanized Channels
- EATON Dashpots
- EATON CHB Series Bolt-On Mount Circuit Breakers
- Cementex USA Insulated Files
- LINCOLN Battery Chargers
- KEYSCO TOOLS Spot Weld Cutter Sets
- MORSE DRUM Taper Lock Bushings
- BALDOR / DODGE VSC Ball Bearings