EATON BAB Series Thermal Magnetic Circuit Breakers
Eaton BAB Series thermal-magnetic circuit breakers are designed to protect electrical equipment and systems from damage due to short circuits and overcurrent conditions. They use both thermal and magnetic elements to detect and interrupt the circuit. These circuit breakers can be installed on d...evices using a bolt-on method, offering easy access to the device for maintenance and replacement and providing a secure, stable mount. They are available in single / double / three pole configurations to meet the needs of various applications.Read more
Style | Model | Amps | Number of Poles | Voltage | Price | |
---|---|---|---|---|---|---|
A | BAB2015D | - | - | - | €311.16 | RFQ
|
B | BAB3060H | - | - | - | €179.47 | |
C | BAB1060V | - | - | - | €134.19 | RFQ
|
C | BAB1060N | - | - | - | €119.60 | RFQ
|
D | BAB1070V | - | - | - | €262.54 | RFQ
|
E | BAB1100 | - | - | - | €101.21 | |
F | BAB2050I | - | - | - | €220.94 | RFQ
|
G | BAB2055 | - | - | - | €291.71 | RFQ
|
H | BAB3055HS | - | - | - | €1,588.88 | RFQ
|
I | BAB3090HI | - | - | - | €968.16 | RFQ
|
B | BAB3060E | - | - | - | €1,452.76 | RFQ
|
H | BAB3055H | - | - | - | €867.38 | RFQ
|
J | BAB1050S | - | - | - | €797.37 | RFQ
|
H | BAB3050HV | - | - | - | €1,102.69 | RFQ
|
K | BAB2050D | - | - | - | €365.61 | RFQ
|
H | BAB3040HI | - | - | - | €687.67 | RFQ
|
H | BAB3040HS | - | - | - | €427.62 | |
L | BAB3080HT | - | - | - | €1,246.60 | RFQ
|
M | BAB2005 | - | - | - | €392.85 | RFQ
|
N | BAB2040H | - | - | - | €618.45 | RFQ
|
O | BAB2080S | - | - | - | €333.82 | |
P | BAB2020D | - | - | - | €295.62 | RFQ
|
Q | BAB2015T | - | - | - | €287.83 | RFQ
|
R | BAB2100HI | - | - | - | €846.55 | RFQ
|
O | BAB2080S1 | - | - | - | €1,409.96 | RFQ
|
S | BAB2090HI | - | - | - | €846.55 | RFQ
|
O | BAB2080H | - | - | - | €939.33 | RFQ
|
T | BAB2070S | - | - | - | €290.21 | |
U | BAB2060T | - | - | - | €365.61 | RFQ
|
V | BAB2080 | - | - | - | €146.43 | |
L | BAB3100N | - | - | - | €1,244.67 | RFQ
|
L | BAB3100HSV | - | - | - | €1,993.40 | RFQ
|
L | BAB3100HS | - | - | - | €454.92 | |
L | BAB3100E | - | - | - | €1,810.60 | RFQ
|
W | BAB2060HT | - | - | - | €873.20 | RFQ
|
X | BAB1100N | - | - | - | €170.16 | RFQ
|
Y | BAB1030T | - | - | - | €134.19 | RFQ
|
Z | BAB1030E | - | - | - | €217.81 | RFQ
|
A1 | BAB3015HD | - | - | - | €488.15 | RFQ
|
B1 | BAB1000 | - | - | - | €46.12 | RFQ
|
C1 | BAB3025C | - | - | - | €556.21 | RFQ
|
D1 | BAB3025HT | - | - | - | €1,036.58 | RFQ
|
E1 | BAB1006 | - | - | - | €239.21 | RFQ
|
F1 | BAB2025S | - | - | - | €238.20 | |
G1 | BAB1015HE | - | - | - | €264.50 | RFQ
|
H1 | BAB2030HE | - | - | - | €1,304.96 | RFQ
|
A1 | BAB3015HV | - | - | - | €906.28 | RFQ
|
I1 | BAB2030HV | - | - | - | €847.92 | RFQ
|
J1 | BAB2030CH08 | - | - | - | €404.52 | RFQ
|
K1 | BAB3020E | - | - | - | €1,507.21 | RFQ
|
K1 | BAB3020HE | - | - | - | €1,746.42 | RFQ
|
L1 | BAB2025V | - | - | - | €365.61 | RFQ
|
R | BAB2100I | - | - | - | €561.04 | RFQ
|
M1 | BAB2100V | - | - | - | €873.20 | RFQ
|
N1 | BABF1020 | - | - | - | €315.06 | RFQ
|
O1 | BAB1015D | - | - | - | €140.99 | RFQ
|
P1 | BAB1015V | - | - | - | €138.08 | RFQ
|
Q1 | BAB2040D | - | - | - | €365.61 | RFQ
|
H | BAB3030HS1 | - | - | - | - | RFQ
|
R1 | BAB2045 | - | - | - | €91.34 | |
S1 | BAB2035S | - | - | - | €238.20 |
Working Mechanism
- These circuit breakers use a combination of thermal and magnetic technology to detect and interrupt overcurrents.
- The thermal element (bi-metallic strip) responds to prolonged overcurrents by monitoring the heat generated by the current flowing through the circuit breaker.
- The magnetic element (electromagnet) responds to sudden, large overcurrents by monitoring the magnetic field generated by the current.
- If the temperature exceeds a certain threshold, both thermal and magnetic elements will trip and open the circuit.
Frequently Asked Questions
How to reset the circuit breaker once tripped?
Users can manually reset the circuit breaker after clearing the fault by pushing the toggle at the centre of the circuit breaker.
What are non-interchangeable circuit breakers?
Non-interchangeable circuit breakers have unique characteristics and ratings that are matched to meet the specific requirements of the equipment. Hence, they are not suitable for replacing or substituting with a different type of circuit breaker without compromising the safety or performance of the electrical system or equipment.
We are here to help!
Looking for a part not listed here?
Explore More
- Routing End Mills
- Concrete Trowels
- Enclosure Heaters
- Snap Action Switches
- Flange Coupling Kit
- Diaphragm Pumps
- Stock Picking and Putaway Carts
- Drum and Barrel Pumps
- Ergonomics
- Exterior Paints and Stains
- GEORG FISCHER Tee, CPVC
- APPROVED VENDOR Wall Mounted Wire Shelving, 2 Shelves
- APPROVED VENDOR Trigger Sprayer Package Quantity 6
- SCHNEIDER ELECTRIC Rotating Mirror Beacon, LED, 120VAC
- APPROVED VENDOR Boiler Gauge Square
- DAYTON Piston Seal Kits
- SHANNON INSULTECH Acoustic Blankets
- BALDOR / DODGE Bronzoil, Flange, Solid Journal Bearings
- BALDOR / DODGE GT, Piloted Flange Grip Tight Adapter Ball Bearings
- BROWNING B Series Gripbelt Sheaves With Split Taper Bushings, 3 Grooves