DURAC Safety Combined Form Hydrometers


Filter
Length: 381mm
StyleModelAccuracyRangeScaleScale DivisionsTemp.Temp. RangePrice
A
50910
+/-0.0010.600/0.710Specific Gravity0.00160 Degrees F/15 Degrees C0 to 150 Degrees F€123.11
A
50925
+/-0.0010.900/1.000Specific Gravity0.00160 Degrees F/15 Degrees C0 to 150 Degrees F€139.58
A
50920
+/-0.0010.800/0.910Specific Gravity0.00160 Degrees F/15 Degrees C0 to 150 Degrees F€134.01
A
50935
+/-0.0021.200/1.420Specific Gravity0.00260 Degrees F/15 Degrees C0 to 150 Degrees F€113.83
A
50940
+/-0.0021.400/1.620Specific Gravity0.00260 Degrees F/15 Degrees C0 to 150 Degrees F€117.14
A
50945
+/-0.0021.600/1.820Specific Gravity0.00260 Degrees F/15 Degrees C0 to 150 Degrees F€133.34
A
50930
+/-0.0021.000/1.220Specific Gravity0.00260 Degrees F/15 Degrees C0 to 150 Degrees F€101.84
A
50950
+/-0.0021.800/2.000Specific Gravity0.00260 Degrees F/15 Degrees C0 to 150 Degrees F€128.48
B
4860
+/-0.1 Degrees59/71API0.160 Degrees F/15 Degrees C0 to 150 Degrees F€128.93
B
4845
+/-0.1 Degrees29/41API0.160 Degrees F/15 Degrees C0 to 150 Degrees F€100.94
B
4865
+/-0.1 Degrees69/81API0.160 Degrees F/15 Degrees C0 to 150 Degrees F€125.78
B
4850
+/-0.1 Degrees39/51API0.160 Degrees F/15 Degrees C0 to 150 Degrees F€98.82
C
4450
+/-0.1 Degrees0/12Brix Sugar Scale0.120 Degrees C0 to 50 Degrees C€113.98
C
4455
+/-0.1 Degrees9/21Brix Sugar Scale0.120 Degrees C0 to 50 Degrees C€122.14
C
4470
+/-0.1 Degrees39/51Brix Sugar Scale0.120 Degrees C0 to 50 Degrees C€122.14
B
4835
+/-0.1 Degrees9/21API0.160 Degrees F/15 Degrees C0 to 150 Degrees F€118.98
B
4840
+/-0.1 Degrees19/31API0.160 Degrees F/15 Degrees C0 to 150 Degrees F€107.72
B
4855
+/-0.1 Degrees49/61API0.160 Degrees F/15 Degrees C0 to 150 Degrees F€102.09

Safety Combined Form Hydrometers

Durac Safety combined form hydrometers measure temperature and relative density of liquids compared to water in food & beverage, chemical, pharmacology, transportation and refrigeration industries. They have lead free ballast and glass construction with mercury-free blue spirit organic liquid for accurate measurements. These hydrometers measure temperature in the range of 0 to 150 degrees F or from 0 to 50 degrees C and feature 3 different types of scales for measuring relative densities. A specific gravity scale measures the relative density of liquids compared to the density of water, whereas an API hydrometer measures the specific gravity of petroleum products and a sugar or Brix hydrometer determine sucrose content in a liquid solution.

We are here to help!

Looking for a part not listed here?