Refrigeration Access Valves
Refrigeration access valves provide access to the HVAC system for charging, recovery and evacuation of the refrigerant, as well as for testing and servicing the system. They are installed on
...Read moreRefrigeration Ball Valves
Style | Model | Connection | Connection Size | Length | Outside Dia. | Price | |
---|---|---|---|---|---|---|---|
A | CV11-18FS-18FS | €276.10 | |||||
A | CV5-8FS-8FS | €52.55 | |||||
A | CV4-6FS-6FS | €44.48 | |||||
A | CV7-10FS-10FS | €105.80 | |||||
A | CV9-14FS-14FS | €164.12 |
Transitions
Line Piercing Charging Valves
Union Tee/one End Swagged
Style | Model | Connection | Connection Size | Inside Dia. | Length | Outside Dia. | Prod. Description | Price | |
---|---|---|---|---|---|---|---|---|---|
A | TC-26-16 | €32.87 | |||||||
A | TC-31-12 | €29.75 | |||||||
A | TC-36-12 | €29.87 | |||||||
A | TC-42-12 | €33.55 | |||||||
A | TC-44-12 | €31.11 | |||||||
A | TC-49-11 | €29.09 | |||||||
A | TC-50-11 | €30.65 | |||||||
A | TC-54-11 | €35.04 | |||||||
A | TC-55-11 | €36.67 | |||||||
A | TC-59-10 | €27.62 | |||||||
A | TC-64-10 | €28.82 | |||||||
A | TC-70-12 | €33.19 | |||||||
A | TC-75-9 | €27.43 | |||||||
A | TC-80-10 | €33.84 | |||||||
A | TC-85-9 | €30.54 | |||||||
A | TC-90-7 | €28.64 | |||||||
A | TC-100-10 | €33.32 |
Automotive Service Connector
Coupler 1/4 Qc
Copper Tube Extension 2 Inch Length
Refrigeration Access Valves
Access Valve Half Union Mpt
Access 1/8 Outer Diameter
Quick Couplers
Frequently Asked Questions
What are JB's valves made of?
JB ball valves feature a brass body construction that resists corrosion and offers durability as well as long-lasting performance.
What is the function of spring-loaded check valves?
When refrigerant flows through the valve in the correct direction, the pressure pushes the ball up against the spring, which allows the refrigerant to flow through the valve uninterrupted. However, if there is a pressure differential in the opposite direction, the spring pushes the check valve down onto the valve seat, preventing the refrigerant from flowing back through the valve.
What is a capillary tube?
Capillary tubes are located between the condenser and the evaporator in a refrigeration system. It controls the flow of refrigerant from the high-pressure side of the system to the low-pressure side, thus providing a pressure drop to help the refrigerant to evaporate and cool.
Explore More
- Distribution Equipment
- Dust Mops Dusters and Cleaning Pads
- Compressed Air Treatment
- Starters and Contactors
- Specialty Paints Coatings and Additives
- Wire Wrap and Unwrap Tools
- Finned Strip Heaters
- Manhole Cover Accessories
- Jib Crane Components
- Pneumatic Controllers
- 3M Replacement Pods
- DIXON Buna Gaskets
- CHRISLYNN Precision Plug Taps, UNC
- BALDOR MOTOR 50Hz Motors, C-Face NEMA Frame Three Phase
- ULTRATECH Lids
- MORSE DRUM Cast Iron Chain Wheels
- ABILITY ONE Grip Wraps
- APW WYOTT Sleevings
- IDEAL Crimpers