Laboratory Ovens and Furnaces | Raptor Supplies

Laboratory Ovens And Furnaces

Filter

Laboratory ovens and furnaces are specialised equipment ideal for heating materials in a controlled environment. They are used in material testing and sterilization & drying...Read more

StyleModelCapacityOverall DepthOverall HeightOverall WidthTemp. AccuracyWattsPrice
ASMO3327"35.5"28.6"+/- 2.0 Degrees C at 150 Degrees C2000€5,292.79
ASMO54.927.5"40"30.5"+/- 2.5 Degrees C at 150 Degrees C2200€6,256.54
LABCONCO -

Sensors

StyleModelPrice
A736582000€468.25
A736581000€468.25
VELP SCIENTIFIC -

Plates

StyleModelPrice
AA00000339€297.91
BA00000338€266.66
CA00000341€248.46
DA00000340€316.80
LABCONCO -

Shelfs

StyleModelPrice
A730151010€2,828.21
A730152010€2,828.21
A730151000€2,828.21
B7426400€290.81
A730152000€2,828.21
VELP SCIENTIFIC -

Lab Hot Plates

StyleModelItemPrice
AF20710553Hot Plate€767.04
BF20510531Magnetic Stirrer€4,061.43
CF20510530Magnetic Stirrer€4,911.45
DF20710430Plate€1,260.66
ESC20510554Stirrer€1,369.10
FF20510551Stirrer€886.06
GSA20510554Stirrer€1,041.71
HF20510554Stirrer€993.58
QUINCY LAB -

Motors

StyleModelItemPrice
A205-2030Motor€181.18
RFQ
B401-2025Motor Assembly€187.82
RFQ
LABCONCO -

Adapters

StyleModelPrice
A7547600€94.04
A7547400€94.13
HEIDOLPH -

Oils

StyleModelPrice
A036110410€752.75
B036110390€794.48
C036110430€620.10
StyleModel
VELP SCIENTIFIC -

Bowls

StyleModelPrice
AA00000331€322.98
BA00000332€378.89
CA00000333€386.81
DA00000330€320.16
EA00000375€1,771.74
DA00001073€310.14
DA00001071€208.73
DA00001072€231.76
FA00000334€423.58
GA00000374€1,038.82
LABCONCO -

Shelves

StyleModelPrice
A780801030€14,734.26
A780801070€15,728.82
A780801050€15,728.82
A780801015€15,728.82
B780801140€21,642.52
A780801010€15,728.82
B780801100€20,274.03
B780801115€21,642.52
B780801110€20,734.88
A780801000€14,734.26
B780801150€21,642.52
B780801130€20,734.88
A780801040€15,728.82
B780801170€21,642.52
SHEL LAB -

Oven Vacuum

StyleModelNumber of ShelvesOverall DimensionsPower RequirementTemp. AccuracyTemp. RangeVolumePrice
ASVAC1E215.5 x 19 x 22.5"115V+/- 9 Degrees C at 120 Degrees CAmb. +15 Degrees C to 210 Degrees C0.6 cu. ft.€4,038.86
BSVAC1317 x 22.3 x 23.5120v 60 hz+/- 3.5% of set pointAmb. +10 Degrees to 240 Degrees C0.6 cu. ft.€8,556.04
CSVAC4326.5 x 35 x 32.5120v 60 hz+/- 3.5% of set pointAmb. +10 Degrees to 240 Degrees C4.5 cu. ft.€20,762.99
CSVAC2320.5 x 28.2 x 26.25120v 60 hz+/- 3.5% of set pointAmb. +10 Degrees to 240 Degrees C1.7 cu. ft.€11,774.86
GLAS COL -

Lab Heating Mantles

StyleModelItemPrice
A100A O396Heating Mantle€409.26
B100A O414Heating Mantle€812.12
A100A O398Heating Mantle€349.79
C100A O408Heating Mantle€483.45
C100A O410Heating Mantle€528.96
D100D SI05Heating Mantle€343.26
E100B TM114Heating Mantle€1,041.29
D100D SI02Heating Mantle€277.38
B100A O406Heating Mantle€533.03
A100A O394Heating Mantle€314.74
F100B TM118Heating Mantle€2,222.06
G100D SI22Heating Mantle€498.95
H100B TM110Heating Mantle€698.08
H100B TM108Heating Mantle€590.57
F100B TM116Heating Mantle€2,176.79
G100D SI12Heating Mantle€416.99
A100A O402Heating Mantle€384.85
I100A O416Heating Mantle€1,640.01
H100B TM106Heating Mantle€557.08
H100B TM102Heating Mantle€483.45
J100A MO1143Top€973.78
K100A INS1163Top€1,161.41
J100A MO1163Top€1,612.26
K100A INS1103Top€485.03
L100A INS1183Top€1,317.05
StyleModelPower RequirementTemp. RangePrice
ASVAC2E115VAmb. +15 Degrees C to 210 Degrees C€4,895.55
ASVAC2E-2240VAmbient +15C to 210 Degrees C€5,342.83
APPROVED VENDOR -

Laboratory Bench Ovens

StyleModelOverall DimensionsPower ConsumptionTemp. RangeVolumePrice
A5DNY933 x 24 x 35.51110 Watts MinimumAmbient to149 Degrees C7.0 cu. ft.€5,645.99
B5DNY733 x 24 x 35.51110 Watts MinimumAmbient to 225 Degrees C7.0 cu. ft.€4,519.74
A5DNZ533 x 24 x 35.5"2800 Watts MinimumAmbient to 225 Degrees C6.6 cu. ft.€6,990.34
APPROVED VENDOR -

Laboratory Oven, Forced Airs

StyleModelOverall DimensionsPower ConsumptionPower RequirementTemp. AccuracyVolumePrice
A5DNW914 x 20.5 x 12"800 Watts Minimum230V, 50/60 Hz+/-20.6 cu. ft.€1,958.51
A5DNX315 x 24.5 x 15"1000 Watts Minimum230V, 50/60 Hz+/-11.14 cu. ft.€2,284.21
A5DNX720 x 28.5 x 14"1600 Watts Minimum230V, 50/60 Hz+/-12.0 cu. ft.€2,681.73
A5DNX620 x 28.5 x 14"1600 Watts Minimum115V, 60 Hz+/-12.0 cu. ft.€2,612.26
StyleModelOverall DimensionsPower ConsumptionPower RequirementTemp. RangeVolume
A5DPA028 x 28 x 371600 Watts120V, 50/60 Hz, 16 A35 to 260 Degrees C3.8 cu. ft.
RFQ
A5DPA128 x 28 x 371800 Watts240V 50/60 Hz, 9.2 A35 to 260 Degrees C3.8 cu. ft.
RFQ
A5DPA236 x 30 x 42"2400 Watts240V 50/60 Hz, 11.7 A35 to 260 Degrees C6.7 cu. ft.
RFQ
A5DPA336 x 33 x 54"3600 Watts240V 50/60 Hz, 18.4 A50 to 260 Degrees C12.0 cu. ft.
RFQ
SHEL LAB -

Basic Digital Ovens

StyleModelNumber of ShelvesOverall DimensionsTemp. AccuracyVolumePrice
ASMO14-2337X34X47+/- 3.0 Degrees C @ 150 Degrees C13.7 cu. ft.€10,327.96
BSMO28-2637.5x24.75x78.25+/- 3.5 Degrees C at 150 Degrees C27.5 cu. ft.€12,707.38
RFQ
BENCHMARK SCIENTIFIC -

Lab Hot Plates

StyleModelItemPrice
AH3710-H-EHot Plate€807.50
BIPS7000-10-EHot Plate€2,706.44
CIPS7000-5-EHot Plate€1,860.60
DH3710-HHot Plate€799.26
CIPS7000-5Hot Plate€1,860.60
BIPS7000-10Hot Plate€2,706.44
DH3710-HS-EStirrer€1,124.13
EH3710-HSStirrer€1,112.72
HUMBOLDT -

Gravity Convection Lab Ovens

StyleModelOverall DimensionsPower ConsumptionPower RequirementTemp. AccuracyVolumePrice
AH-30100------
RFQ
BH-30100.4F14 x 17 x 12"600 Watts Minimum230V, 50/60 Hz+/-20.7 cu. ft.€1,190.73
BH-3011015 x 21 x 15"800 Watts Minimum115V, 60 Hz+/-11.27 cu. ft.€1,397.83
BH-30110.4F15 x 21 x 15"800 Watts Minimum230V, 50/60 Hz+/-11.27 cu. ft.€1,494.68
BH-3012020 x 25 x 14"1200 Watts Minimum115V, 60 Hz+/-12.0 cu. ft.€1,789.61
BH-30120.4F20 x 25 x 14"1200 Watts Minimum230V, 50/60 Hz+/-12.0 cu. ft.€1,846.98
CH-3012820 x 30 x 16"1600 Watts Minimum115V, 60 Hz+/-13.0 cu. ft.€2,085.88
CH-30128.4F20 x 30 x 16"1600 Watts Minimum230V, 50/60 Hz+/-13.0 cu. ft.€2,143.86

Frequently Asked Questions

What is the difference between a laboratory oven and a laboratory furnace?

Laboratory ovens are used for heating materials at lower temperatures, generally up to about 300 to 400 degrees C. Laboratory furnaces, on the other hand, are used for heating materials at higher temperatures, generally above 600 degrees C.

What are some safety instructions to follow while operating these laboratory ovens and laboratory furnaces?

  • Monitor the temperature inside the oven or furnace and ensure that it is stable & accurate.
  • Clean the oven or furnace regularly to remove dust, debris or spills.
  • Check for any signs of wear or damage.
  • Calibrate these units periodically.

Can laboratory ovens and furnaces be used for continuous operation?

Most of the laboratory ovens and furnaces are suitable for batch-style operation, where the materials are loaded into the oven or furnace, heated and then removed. However, some industrial-grade units can be used for continuous operation and support the loading & unloading of materials while the heating is ongoing.